The MOS device length, width, source area and drain area will default to common values if not specified for a device. These values are set by the following variables:
Variable | Purpose | Default |
---|---|---|
defad | drain area | 0 M2 |
defas | source area | 0 M2 |
defl | gate length | 1 uM |
defw | gate width | 1 uM |