Next: Initial Conditions
Up: Transmission Lines (General)
Previous: Model Level
Contents
Index
- len
This provides the physical length of the transmission line in
arbitrary units, though the units must match the per-length unit in
the element values discussed below. If not given, the value is taken
as unity, unless it is implicitly defined by other parameters.
- l
This parameter provides the series inductance per unit length of the
line. The default is 0.
- c
This parameter provides the shunt capacitance per unit length of the
line. The default is 0.
- r
This parameter provides the series resistance per unit length of the
line. The default is 0.
- g
This parameter provides the shunt conductance per unit length of the
line. The default is 0. With level 2, this cannot be nonzero if
l or c is given, i.e., only r can be nonzero if
g is nonzero for level = 2, as in the SPICE3 LTRA model.
- z0 or zo
This is the line (lossless) characteristic impedance in ohms, given by
Z0 =
- td or delay
This is the (lossless) phase delay of the line in seconds, given by
Td =
Length
- nl
This is the normalized line length at a particular frequency f,
which must also be specified (see below). This is an alternative
means for setting the line delay, where
Td = nl /f
It is an error to give both td and nl.
- f
This is the frequency at which the normalized line length (above) is
representative.
To model a line with nonzero series inductance and shunt capacitance,
a complete but non-conflicting subset of the parameters l, c, z0, td, len, f, and nl must be
provided. The td parameter is the line delay in seconds, and
the z0 parameter is the impedance in ohms, for the lossless
case. Specifying these two parameters is sufficient to completely
specify a lossless line, or the reactive elements of a lossy line.
Alternatively, one could specify l (inductance per length), c (capacitance per length) and len (line length). If len
is not specified in either case, the length defaults to unity. The
delay can also be specified through the f (frequency) and nl (normalized length) parameters, where the delay would be set to
nl/f. It is an error to specify both td and f, nl. If td is specified, or both f and nl are
specified, along with parameters which yield internally the L and C
values, then the length is determined internally by
Length =
Td/
One can specify z0 and l, for example, which determines C.
Unlike the SPICE3 (and SPICE2) lossless line devices, the delay must
be specified through the parameters; there is no default.
Next: Initial Conditions
Up: Transmission Lines (General)
Previous: Model Level
Contents
Index
Stephen R. Whiteley
2024-10-26