For each cell comparison, the LVS system reports four levels of
success.
- CLEAN
Everything was measurable and matched.
- PASSED - AMBIGUITY
There were device parameters which could not be compared, but all
comparisons that were done matched.
In the electrical schematic, if component values are
parameterized (i.e., use a token defined in a .param
line or similar), or perhaps use WRspice shell
expansion, the value was unavailable. In earlier releases, a
value was available only if it was a numeric constant.
Xic now provides limited parameter substitution during
LVS (see below).
- PASSED - PARAM DIFFS
There were device parameters that differ outside of the
tolerance between electrical and physical. So actually, only
the circuit topological check passed.
- FAILED
Differences in circuit topology were detected.
The overall result for the run is the lowest level in this hierarchy
reported for any cell.
The parameter database and substitution code was imported from
WRspice for use during LVS and elsewhere. However, not all
capability can be provided.
- Parameters given in subcircuit call lines are ignored in LVS,
making LVS meaningless if these are given in the schematic.
Parameterized instances must be remastered to unique master cells
for the current LVS system.
- There is presently no support for macros defined in
.param lines. However, single-quoted expressions are
fully supported, all math operations and all relevant functions
are available.
Parameter expansion works as follows:
- When an LVS run starts, the parameters defined in the top-level
cell as param properties, and all parameters defined in .param lines found in labels on the SPTX layer in the top level
cell, are placed in a table.
In addition, the labels on the SPTX layer are searched for .option lines, and these lines are searched for a parhier
option, and if found, its setting is saved. This option can be set
to one of ``global'' (the default if not found) or ``local''.
- When comparing devices in the top-level cell, the parameter
table is used to parameter substitute the value and param
property strings. The resulting string should provide numerical
values for comparison to the extracted physical values.
- When comparing in a subcell/subcircuit, the subcircuit param properties and .param labels are tabulated as for the
top-level cell. This is merged with the top-level table, and is used
to expand the param and value property strings of devices
in the cell.
If the parhier option was found, and it was set to local,
then parameters defined in the subcircuit table will override
conflicting definitions in the top level table. If parhier
wasn't found or was set to global, the reverse is true -
top-level definitions will override conflicting definitions in the
subcell.
The output file produced by LVS contains a block of lines for each
cell in the hierarchy where there is both electrical and physical
information. Each block may contain several tables, which provide
information about the cell and the electrical/physical associations.
These tables are described below.